Two independent sensor sets
No single camera, radar or lidar failure can blind the vehicle.
Most autonomy programs start at the top, proving perception, and never build the layer that actually moves the vehicle. We build that layer first: a safety-rated vehicle controller, the diagnostics, the update path and the approvals. Every step toward Level 4 and robotaxi service reuses it.
A Level 2 system hands control back to the driver when something goes wrong. At Level 4 there is nobody to hand back to. A second, independent path has to bring the vehicle to a safe stop on its own, with its own sensors and its own power. That is fail-operational, and it decides the whole design.
No single camera, radar or lidar failure can blind the vehicle.
CVC-2 Fail-op runs two independent computers on two power nets, targeting ASIL D fail-operational.
By-wire actuators with redundancy, commanded through the same permission pattern as every CVC.
The vehicle can always finish to a standstill in a safe place, without a driver.
A fleet control centre watches faults, early warnings and market issues across every vehicle.
The same torque safety concept, fault-code catalogue and update path as the CVC controllers already in vehicles.
Each step adds sensors, compute and functions to the one below it. Every request still passes the safety gate in the vehicle controller: an ADAS controller never drives an actuator directly.
| Controller | Level | Target | Sensors | Compute | Safety |
|---|---|---|---|---|---|
| ADC-L2 | L2 | The mandated L2 set: AEB, lane keeping, ISA, blind spot, ACC, driver drowsiness | Front camera, front radar, 4 corner radars, driver camera | ≈ 5–10 TOPS + ASIL-D safety MCU | ASIL B perception, ASIL D requests |
| ADC-L2 + Parking | L2 + parking | As L2, plus automated and remote parking | + 4 surround cameras, 12 ultrasonic | ≈ 10–20 TOPS + safety MCU | ASIL B / D |
| ADC-L2+ | L2+ | Highway and traffic-jam assist, hands on | L2 + parking set | ≈ 20–40 TOPS + safety MCU | ASIL B / D |
| ADC-L2++ | L2++ | Hands-off highway, navigate-on-autopilot, system lane change | 11 cameras, 5 radars, 12 ultrasonic, lane-level map, GNSS/IMU | ≈ 80–200 TOPS + safety MCU | ASIL B(D) decomposed, ASIL D requests |
| ADC-L3 | L3 | Conditional automation in a declared domain (UN R157) | L2++ set + lidar + redundant front sensing | ≥ 250 TOPS + safety MCU with fallback trajectory | ASIL D, fail-operational during handover |
| ADC-L4 | L4 | Driverless in a declared domain: depot, port, mine, campus | Two independent sensor sets | Two independent computers, separate power | ASIL D fail-operational |
Constrained domains are real businesses with a labour problem today. On a private site there is no vehicle type approval for automated driving to obtain, because the vehicle is not on a public road. The first Level 4 revenue comes from where the law is already settled.
Bus and truck yards: parking, charging and wash-bay moves without a driver.
Container tractors on fixed routes inside a fenced terminal.
Haulage on private roads, where driver shortages and safety risks are highest.
Shuttles in factory, airport and university campuses at low speed.
A robotaxi is a Level 4 vehicle in a geofenced city domain, run as a fleet. We supply the parts that make it safe, approvable and serviceable, and let operators and AI partners build on them.
We are also working toward our own Level 4 vehicle platform and robotaxi
CVC-2 Fail-op, with CVC-1e zone controllers handling body and power around the vehicle.
ADC-L4: two independent sensor sets with cameras, radar and lidar, and a rated checker behind every learned function.
Remote supervision, fault early warning and market issues across the fleet, around the clock.
Signed A/B updates to every controller, under UN R155 and R156 cybersecurity and update rules.
Rare and disagreement scenes are selected and uploaded for training, without identifying any customer.
ISO 26262, ISO 21448 (SOTIF), ISO/SAE 21434 and Automotive SPICE work products, built once and reused at every level.
Perception and planning, developed under quality management.
Plausibility and limit checks on every request, safety-rated.
The CVC's ASIL-D partition grants or clamps each request.
Redundant steering and braking, with a fallback path.
CVC-1e in series vehicles: the safety core, diagnostics and update path.
FIRSTADAS controllers on the same gate, in passenger and commercial vehicles.
NEXTCVC-2 Central with CVC-1e zones, as in the LERA T1.
PLATFORMCVC-2 Fail-op and ADC-L4 in depots, ports, mines and campuses.
L4Our Level 4 vehicle platform in geofenced public-road service with fleet partners, where regulators permit driverless operation.
FLEETLevel 3 and Level 4 products are on our roadmap and are not yet available. Figures are engineering targets; ASIL ratings are design targets pending independent functional-safety assessment. Driverless public-road operation depends on local regulation in each market.
Fleet operators, vehicle makers and AI companies: talk to us about the vehicle controller, the fail-operational computer and the approval work underneath your autonomy stack.